The energy saving is ensured by the DC Inverter technology which lead to a save up to 40%.
R410A DC INVERTER FLOOR & CEILING TYPE AIR CONDITIONER HEAT-PUMP12000BTU 18000BTU 24000BTU 36000BTU 48000BTU 60000BTU
The energy saving is ensured by the DC Inverter technology which lead to a save up to 40%.
All the versions have both cooling and heat pump function.
DC Inverter versatile air conditioner, that allows the installation of the indoor unit on the floor as well as on the ceiling, without any technical modification. This model is the ideal solution for all cases in which in a store or in the office, the walls are occupied by cabinets or bookshelves.
R410A DC INVERTER FLOOR & CEILING TYPE AIR CONDITIONER HEAT-PUMP | |||||||||
Model | UCHA-09FDC | UCHA-12FDC | UCHA-18FDC | UCHA-24FDC | UCHA-36FDC | UCHA-48FDC | UCHA-60FDC | ||
Power supply | Ph-V-Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | ||||||
3, 380~415V, 60Hz | |||||||||
Cooling | Capacity | BTU | 8870(2380-9890) | 119400(3400-13300) | 17000(7840-19700) | 23200(12690-29000) | 10400(5000-12000) | 13800(6000-14200) | 17000(6500-18500) |
Input | W | 710(270-1000) | 960(270-1580) | 1440(750-2200) | 2131(1300-3450) | 3313(2100-4350) | 4647(2500-4950) | 5762(2600-6500) | |
Rated current | A | 3.4(1.5~4.5) | 4.36(1.5~6.85) | 6.55(3.4~10.0) | 9.2(6.0~16.0) | 14.7(9.5-18.9) | 20.2(11.6-22.5) | 25.05(12.1-28.9) | |
EER | BTU/W | 12.48 | 12.41 | 11.83 | 10.88 | 10.71 | 10.13 | 10.06 | |
Heating | Capacity | BTU | 9550(3070-10500) | 12960(3680-15350) | 18420(8180-21500) | 24500(13640-31000) | 10700(6000-12000) | 14300(6300-14400) | 17600(8100-19100) |
Input | W | 824(260-1100) | 1172(260-1680) | 1700(675-2280) | 2320(1310-3600) | 3507(2400-4600) | 4912(2050-5600) | 6170(2780-6800) | |
Rated current | A | 3.6(1.4-5.0) | 5.1(1.5-7.32) | 7.4(3.5-11.2) | 9.7(6.1-16.3) | 15.5(10.4-20.5) | 21.3(8.9-24.8) | 26.82(12.9-29.5) | |
COP | BTU/W | 11.56 | 11.05 | 10.84 | 10.57 | 10.41 | 9.92 | 9.72 | |
SEER | BTU·h/W·h | 21.49 | 20.06 | 17.91 | 16.93 | 15.96 | 15.01 | 14.23 | |
Indoor air flow | CFM | 411 | 411 | 500 | 576 | 676 | 811 | 970 | |
Dehumidification Capacity in Cooling mode | Outdoor ambient temperature: DB95℉(35℃)/WB75℉(23.9℃),RH 40%; Indoor ambient temperature: DB80℉(26.7℃)/WB67℉(19.4℃),RH 51%. | L/H | 0.85 | 1.08 | 2.64 | 2.95 | 3.65 | 4.56 | |
Dehumidification Capacity in dehumidification mode | L/H | 0.45 | 0.65 | 1.36 | 1.5 | 2.1 | 2.63 | ||
Dehumidification Capacity in Cooling mode | Outdoor ambient temperature: DB81℉(27℃)/WB75℉(24℃),RH 78%; Indoor ambient temperature: DB81℉(27℃)/WB75℉(24℃),RH 78%. | L/H | 1.8 | 2.2 | 4.95 | 5.65 | 6.6 | 8.25 | |
Dehumidification Capacity in dehumidification mode | L/H | 1.2 | 1.46 | 3.58 | 3.9 | 4.5 | 5.63 | ||
Indoor unit | Dimension (W*H*D) | Inch | 37.1×26.2×9.5 | 37.1×26.2×9.5 | 37.1×26.2×9.5 | 52×26.2×9.5 | 52×26.2×9.5 | 66.9×26.2×9.5 | 66.9×26.2×9.5 |
Packing (W*H*D) | Inch | 38.8×29.6×12.3 | 38.8×29.6×12.3 | 38.8×29.6×12.3 | 53.6×29.8×12.1 | 53.6×29.8×12.1 | 69×30×12.3 | 69×30×12.3 | |
Net/Gross weight | Ibs | 78.7/82.2 | 85.5/92.5 | 97.8/101.5 | 106.8/120.8 | 113.6/117.9 | 126.0/131.0 | 139.5/146.5 | |
Outdoor unit | Dimension (W*H*D) | Inch | 31.2X21.5X9.8 | 31.2X21.5X9.8 | 34.1X24X12.3 | 32.37X12.1X27.7 | 34.3×14×31.2 | 49.5X36.3X15.2 | 49.5X36.3X15.2 |
Packing (W*H*D) | Inch | 34.7X25.5X14 | 34.7X25.5X14 | 38.2X26.9X15.8 | 38.2X35.5X18.1 | 40.1×17.6×32.6 | 49.9X41.73X19.1 | 1280X1070X490 | |
Net/Gross weight | Ibs | 85.5/92.5 | 94.5/101.2 | 117.0/121.5 | 148.5/152.8 | 144.3/149.5 | 229.5/249.7 | 239.5/258.5 | |
Noise level | Indoor | dB(A) | 30-42 | 30-42 | 32-47 | 33-48 | 35-49 | 36-50 | 36-52 |
Outdoor | dB(A) | 46 | 48 | 53 | 55 | 57 | 59 | 59 | |
MAX FUSE SIZE | A | 10 | 15 | 15 | 20 | 25 | 35 | 40 | |
MAX.Pipe Length | Ft | 26.25 | 32.81 | 32.81 | 49.21 | 49.21 | 65.62 | 82.02 | |
MAX.Height Difference | Ft | 16.40 | 26.25 | 26.25 | 32.81 | 32.81 | 49.21 | 49.21 | |
Pipe Size Liquid/Gas | Inch | 1/4 - 3/8 | 1/4 - 1/2 | 1/4 - 1/2 | 3/4 - 5/8 | 3/4 - 5/8 | 1/2 - 3/4 | 1/2 - 3/4 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | R410a | R410a | ||
Design pressure | Psi | 600 | 600 | 600 | 600 | 600 | 600 | 600 | |
Operation temp | ℉ | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | |
Ambient temp | ℉ | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | |
Application area | Ft2 | 108-140 | 151-237 | 210-324 | 486-648 | 810-972 | 1080-1188 | 1188-1350 | |
Compressor | Model | DA89X1C-20FZ3 | 5RS102ZAA01 | DA130S1C-20FZ | DA150S1C-20FZ | C-7RV153HOW | 5VD420ZAA21 | E405DHD38A2G | |
Type | ROTARY | ROTARY | ROTARY | ROTARY | ROTARY | ROTARY | SCROLL | ||
Brand | GMCC | MATSUSHITA | GMCC | GMCC | SANYO | MATSUSHITA | HITACHI | ||
Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0℉\75.0℉ Indoor dry bulb temperature/Wet bulb temperature80.0℉\67.0℉ | |||||||||
Rated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0℉\43.0℉ Indoor dry bulb temperature/Wet bulb temperature70.0℉\60.0℉ | |||||||||
The difference between the fixed-frequency and frequency of:: | |||||||||
Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow (19-109 ℉) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot. | |||||||||
Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13 - 126 ℉) and can change depending on the temperature and adjust the size of the room cooling / heating capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic climate control, power consumption energy-saving effect is remarkable. | |||||||||
Contact
Supplier