Brand Name:
oem/odm/vkin/utl
Size:
can be customized
Payment by:
30%t/t in advance, 70% t/t before shipment
Delivery time:
within 40 days after 30% t/t in advance received
MOQ:
1x40'hq/model/order
Place of Origin:
guangzhou,china
Brand Name:
oem/odm/vkin/utl
Size:
can be customized
Payment by:
30%t/t in advance, 70% t/t before shipment
Delivery time:
within 40 days after 30% t/t in advance received
MOQ:
1x40'hq/model/order
Place of Origin:
guangzhou,china
Supplier Info.
Registration Date: 2008
Country / Region: guangdong / China
City: guangzhou
Main Products: air handler heat pump air conditioner, inverter heat pump, heat pump manufacturers
Product Detail
/  Product Features

VKIN R410A DC  INVERTER AIR HANDLER AIR CONDITIONER


/  Product Features
  • 01
    kind of split system that adopt DC inverter compressor and with a high SEER of 22 which is far above the ENERGY STAR standard.
  • 02
    Comfortable and Optimized Airflow The duct can connect with multiple diffusers to ensure even distribution of airflow and optimized the air quality.
  • 03
    Removable front panel allows easy access for maintenance and trouble- shooting. Blower and coil assemblies slide out.
  • 04
    Variable speed ECM fan motor delivers just the right amount of air, varying its speed as needed, depending on your comfort requirements.
  • 05
    The indoor unit can be connected to several wired controllers, which can achieve controlling one indoor unit in different control point.
  • 06
    Controlled by remote controller and wired controller together unique control logic makes it possible to control one IDU with remote controller and wired controller together.
undefined
quiet comfort

Insulated cabinet design and aerodynamically engineered blowers ensure quiet comfort.

undefined
Multiple airflow designs

Vertical up-flow/vertical down-flow/horizontal left-flow and horizontal right-flow.Auxiliary electric heaters(5kW, ,15kW, 30kW) with optional filters and thermostats.

undefined
Technology

180° sine wave DC speed varying technology

undefined
DC inverter compressor and control technology

All DC inverter compressor and high-performance high pressure chamber are adopted to reduce loss of overheat and improve compression efficiency from direct intake.

undefined
DC inverter fan motor

Stepless speed regulation ranges from 5Hz to 65Hz.Compared with traditional inverter motors, the operation is more energy-saving.

undefined
Technology of maximum torque control with minimum current

It can reduce energy loss caused by device winding so as to realize higher efficiency.

/  Product parameters
R410A DC  INVERTER AIR HANDLER AIR CONDITIONER
ModelUCHA-18HDCUCHA-24HDCUCHA-30HDCUCHA-36HDCUCHA-48HDCUCHA-60HDC
Power supplyPh-V-Hz1, 230V, 60Hz1,230V,60Hz
3,  380~415V,60Hz
CoolingCapacity          BTU17900(8600-20100)23880(12280-27290)29500(15540-33500)35480(17050-40940)47760(25580-53560)57660(27970-61410)
InputW1455(660-2000)2047(1100-3450)2648(1230-3600)3260(1350-3800)4396(2050-5350)5453(2650-5900)
Rated current A6.4(2.6~8.7)9.3(4.8~16.0)11.5(5.4-15.7)14.3(5.86-16.52)19.11(8.91-23.26)23.98(11.52-25.62)
EERBTU/W12.311.6611.1410.8810.8410.54
HeatingCapacityBTU18900(9200-21200)24900(13640-29000)31600(16400-35120)37530(22170-41960)48790(26610-56630)60000(28650-64140)
InputW1526(720-2240)2080(1150-3600)2757(1310-3720)3395(1420-3950)4450(2190-5510)5660(2780-6150)
Rated current A6.7(3.1-9.7)9.78(5.0-16.36)12.0(5.7-16.1)15.11(6.17-17.17)20.33(9.52-23.94)25.89(12.08-26.73)
COPBTU/W12.3811.9711.4611.0510.9510.61
SEERBTU·h/W·h18.5417.6717.0516.5616.0014.62
Indoor air flow (H/M/L) CFM1000/800/6471000/800/6471500/1294/111051500/1294/111052000/1647/12942176/2000/1764

Dehumidification Capacity 

in Cooling mode

Outdoor ambient temperature: 

DB95℉(35℃)/WB75℉(23.9℃),RH 40%;

Indoor ambient temperature: 

DB80℉(26.7℃)/WB67℉(19.4℃),RH 51%.

L/H1.852.42.642.953.654.56

Dehumidification Capacity 

in dehumidification mode

L/H0.981.21.361.52.12.63

Dehumidification Capacity 

in Cooling mode

Outdoor ambient temperature: 

DB81℉(27℃)/WB75℉(24℃),RH 78%;

Indoor ambient temperature: 

DB81℉(27℃)/WB75℉(24℃),RH 78%.

L/H3.14.354.955.656.68.25

Dehumidification Capacity 

in dehumidification mode

L/H2.23.33.583.94.55.63
Indoor unitDimension (W*H*D)Inch41×21.1×17.941×21.1×17.946.2×22.4×19.946.2×22.4×19.954.2×25×21.754.2×25×21.7
Packing   (W*H*D)Inch41.3×23.8×20.441.3×23.8×20.446.6×25.4×21.946.6×25.4×21.954.6×27.5×24.654.6×27.5×24.6
Net/Gross weightIbs108/121.5108/121.5144.0/159.7144.0/159.7175.5/191.5186.5/205.2
Outdoor unitDimension (W*H*D)Inch34.1X24X12.332.4X27.7X12.134.3X31.2X1434.3X31.2X1449.1X32.4X12.149.5X36.3X15.2
Packing   (W*H*D)Inch38.2X26.9X15.837.8X29.1X1640X32.8X17.840X32.8X17.849.5X37.8X1650X41.7X19.1
Net/Gross weightIbs117.4/125.5104.6/109.1128.2/132.7128.2/132.7211.5/231.7229.5/249.7
Noise levelIndoordB(A)484851525557
OutdoordB(A)39-4740-4840-4941-5046-5347-55
MAX  FUSE SIZEA152025253540
MAX.Pipe LengthFt49.2149.2149.2149.2165.6282.02
MAX.Height DifferenceFt32.8132.8132.8132.8149.2149.21
Pipe Size Liquid/GasInch1/4 - 1/23/4 - 5/83/4 - 5/83/4 - 5/81/2 -  3/41/2 - 3/4
Refrigerant
R410aR410aR410aR410aR410aR410a
Design pressure       Psi600600600600600600
Operation temp       62  -  8862  -  8862  -  8862  -  8862  -  8862  -  88
Ambient temp    -13 - 116-13 - 116-13 - 116-13 - 116-13 - 116-13 - 116
Application areaFt2216-324324-432360-480432-540752-972864-1080
CompressorModel   
5RS102ZAA01DA130S1C-20FZDA150S1C-20FZC-7RV153HOW5VD420ZAA21E405DHD38A2G
Type     
ROTARY ROTARY ROTARY ROTARYROTARY SCROLL
Brand    
MATSUSHITA GMCCGMCCSANYOMATSUSHITA HITACHI

Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0℉\75.0℉

Indoor dry bulb temperature/Wet bulb temperature80.0℉\67.0℉ 


Rated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0℉\43.0℉

Indoor dry bulb temperature/Wet bulb temperature70.0℉\60.0℉ 


The difference between the fixed-frequency and frequency of::

Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow

 (19-109 ℉) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, 

the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot.

Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13-126 ℉) 

and can change depending on the temperature and adjust the size of the room cooling / heating 

capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic 

climate control, power consumption energy-saving effect is remarkable.


Contact