GDRD82
Features: high accuracy; strong anti-interference ability, not subject to temperature
Influence of degree, humidity and wind; installation, adjustment
Trial and easy to use; low power consumption.
Should be used: suitable for highly corrosive liquids, steam, foam
Maximum range: 30m
Measurement accuracy: ±2mm
Antenna material: stainless steel 316L/PTFE diaphragm or stainless steel 316L/FEP diaphragm
Antenna structure: pointed cone vibrator
Frequency range: 80GHz
Signal output: 4~20mA/HART
RS485/MODBUS protocol
Electric source: Two-wire single cavity (4~20)mA (12~30)VDC standard type
(12~30) VDC intrinsic safety type
Four-wire single cavity (RS485) (9~27) VDC standard type
(24±10%) VDC intrinsically safe type
Four-wire two-chamber (4~20)mA (18~25)VDC standard type
Four-wire two-chamber (4~20)mA 24 VDC standard type
Detailed introduction:
GDRD82
License form
P Standard type (non-explosion-proof)
I Intrinsically safe type (Ex ia ⅡC T2~T6 Ga)
G intrinsic safety + flameproof type (Ex d ia [ia Ga] ⅡC T2~T6 Gb)
※See note 1
Antenna type
DS (-40~150)℃ (-0.1~2.5)MPa 50mm lens diameter single-piece heat dissipation
DQ (-40~200)℃ (-0.1~2.5)MPa 50mm lens diameter multi-piece heat dissipation
ES (-40~150)℃ (-0.1~2.5)MPa 80mm lens diameter single-piece heat dissipation
EQ (-40~200)℃ (-0.1~2.5)MPa 80mm lens diameter multi-piece heat dissipation
※See note 4
Lens material
A PTFE(-40~200)℃
B FEP (-40~150)℃
Installation method
FA flange DN50 PN16 GB/T9119-2000 stainless steel 316L
FB flange DN80 PN16 GB/T9119-2000 stainless steel 316L
FC flange DN100 PN16 GB/T9119-2000 stainless steel 316L
FD flange DN125 PN16 GB/T9119-2000 stainless steel 316L
FE flange DN150 PN16 GB/T9119-2000 stainless steel 316L
FX special customization
※See note 3
Process seal
X None
Electronic components
B (4~20)mA/HART two-wire system (single cavity)
C (4~20)mA/24 VDC/HART four-wire system (two chambers)
C (4~20)mA/(18~25)VDC/HART four-wire system (two chambers)
R RS485/MODBUS protocol (single cavity)
X Special customization
※See note 1
Enclosure rating
B Plastic PBT/IP66
A Aluminum ADC12/IP67
G Stainless steel 316L/IP67
D Aluminum two-chamber ADC12/IP67
H stainless steel two-chamber 316L/IP67
※See note 1
Cable entry
M M20x1.5
N ½NPT
Display/programming
A programmer with Bluetooth
B Programmer without Bluetooth
C Remote display with Bluetooth
D Remote display without Bluetooth
X None
※See note 2
Note:
1. Intrinsically safe instruments (Ex ia IIC T2~T6 Ga) are limited to "B, R" electronic components; "A, B, G" housings.
2. Intrinsically safe + flameproof instrument (Ex d ia [ia Ga] ⅡC T2~T6 Gb) is limited to "C, E" electronic components; "D, H" type housing.
3. Lens diameter 50mm, flange diameter minimum DN50, maximum DN100; lens diameter 80mm, flange diameter minimum DN80, maximum DN150.
4. Antenna form DQ and EQ can only use "A" type lens material.
caveat:
1. Intrinsically safe + explosion-proof instrument, the explosion-proof chamber is strictly forbidden to open the cover;
2. The non-metallic parts of the product casing have potential electrostatic charge to prevent the risk of ignition caused by friction and impact; contact with liquid media is strictly prohibited during installation and use; wipe with a damp cloth when cleaning.
3. When the shell contains aluminum ADC12 or plastic PBT, to prevent the risk of ignition caused by impact or friction.
4. During maintenance, the non-metallic parts of the product casing and antenna should avoid the risk of ignition caused by friction or impact.
Contact
Supplier