SE-10W | |||||||
MODEL | AD-S0520AA | AD-S0910AA | AD-S1208AA | AD-S15066AA | AD-S24041AA | AD-S4802AA | |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 2A | 1A | 0.8A | 0.66A | 0.41A | 0.2A | |
Current Range | 0~2A | 0~1A | 0~1A | 0~0.8A | 0~1A | 0~0.5A | |
Rated Power | 24W | 24.03W | 24W | 24W | 24W | 24W | |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% | |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% | |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup/Rise Time | 1000ms,30ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 100ms/220Vac (Full load) | ||||||
Input | Voltage Range | 100~240Vac | |||||
Frequency Range | 50/60Hz | ||||||
Efficiency(Typ.) | 80% | 80% | 85% | 85% | 80% | 80% | |
Ac Current(Typ.) | 0.1A/220Vac | ||||||
Inrush Current(Typ.) | Cold Start: 50A/220Vac | ||||||
Leakage Current(Typ.) | 3mA | ||||||
Protection | Over load protection | 110%~135% | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over Voltage protection | 115%~150% | ||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over-temperature protection | Protected Mode: crystal internal contact temperature exceeds 140℃, turn off the output, when the temperature returns to normal automatic recovery | ||||||
Environment | Working Temp | -10℃~60℃(Refer to "derating curve ") | |||||
Working Humidity | 20~90%RH, non-condensing | ||||||
Storage Temp/Humidity | -30℃~75℃ 10~98%RH, non-condensing | ||||||
Temp Coefficient | ±0.03%℃(0~50℃)(+5V) | ||||||
Vibration | 10Min/1 cycle,period for 60min, each along X, Y, Z axes | ||||||
Safety & EMC(Note 7) | Safety Standards Note 6 | GB4943, EN60950 | |||||
Withstand Voltage | I/P-O/P: 2.5KVAC I/P-FG: 1.5KVAC O/P-FG: 1.5KVAC | ||||||
Isolation Resistance | I/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH | ||||||
EMI Conduction Radiation | Compliance to: EN55022, EN61000-3-2, 3. FCC part15, GB9254 class B, GB17625.1 | ||||||
EMS Immunity | Compliance to: EN61000-4-2, 3, 4, 5, 6, 8, 11, light industry level, criteria A | ||||||
Others | MBTF | ≥10000h. | |||||
Dimension/Packing | 70*40*31mm(L*W*H) /0.1KG;500pcs/50Kg | ||||||
Note | 1.All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation measurement: from 0% to rated load of 100%. 6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for safe use. 7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation. |
SE-12W | |||||||
MODEL | AD-S0524AA | AD-S0913AA | AD-S1210AA | AD-S1508AA | AD-S2405AA | AD-S48025AA | |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 2.4A | 1.3A | 1A | 0.8A | 0.5A | 0.25A | |
Current Range | 0~2.4A | 0~1.3A | 0~1A | 0~0.8A | 0~0.5A | 0~0.25A | |
Rated Power | 12W | 11.7W | 12W | 12W | 12W | 12W | |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% | |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% | |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup/Rise Time | 1000ms,30ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 100ms/220Vac (Full load) |
SE-15W | |||||||
MODEL | AD-S0530AA | AD-S09166AA | AD-S12125AA | AD-S1510AA | AD-S240625AA | AD-S48031AA | |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 3A | 1.66A | 1.25A | 1A | 0.625A | 0.31A | |
Current Range | 0~3A | 0~1.66A | 0~1.25A | 0~1A | 0~0.625A | 0~0.31A | |
Rated Power | 15W | 15W | 15W | 15W | 15W | 14.88W | |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% | |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% | |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup/Rise Time | 1000ms,30ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 100ms/220Vac (Full load) |
SE-18W | |||||||
MODEL | AD-S0536AA | AD-S0920AA | AD-S1215AA | AD-S1512AA | AD-S24075AA | AD-S480375AA | |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 3.6A | 2A | 1.5A | 1.2A | 0.75A | 0.375A | |
Current Range | 0~3.6A | 0~2A | 0~1.5A | 0~1.2A | 0~0.75A | 0~0.375A | |
Rated Power | 18W | 18W | 18W | 18W | 18W | 18W | |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% | |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% | |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup/Rise Time | 500ms,30ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 100ms/220Vac (Full load) |
SE-24W | |||||||
MODEL | AD-S0548AA | AD-S09267AA | AD-S1220AA | AD-S1516AA | AD-S2410AA | AD-S4805AA | |
Output | DC Voltage | 5V | 9V | 12V | 15V | 24V | 48V |
Rated Current | 4.8A | 2.67A | 2A | 1.6A | 1A | 0.5A | |
Current Range | 0~4.8A | 0~2.66A | 0~2A | 0~1.6A | 0~1A | 0~0.5A | |
Rated Power | 24W | 24.03W | 24W | 24W | 24W | 24W | |
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | ±10% | ±10% | |
Voltage Tolerance(Note 3) | ±7% | ±7% | ±6% | ±5% | ±5% | ±5% | |
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±1% | ±1% | ±1% | ±1% | |
Load Regulation(Note 5) | ±2.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Setup/Rise Time | 1000ms,30ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 100ms/220Vac (Full load) |
Contact
Supplier