Products Info
HOME> Home Appliances > Water Heaters > Dc Inverter Integrated Heat Pump Small Commercial Heating Cooling Vrha-100an1dcaio >
Dc Inverter Integrated Heat Pump Small Commercial Heating Cooling Vrha-100an1dcaio

Dc Inverter Integrated Heat Pump Small Commercial Heating Cooling Vrha-100an1dcaio

Brand Name:
oem/odm/vkin/utl
Size:
can be customized
Payment by:
30%t/t in advance, 70% t/t before shipment
Delivery time:
within 40 days after 30% t/t in advance received
MOQ:
1x40'hq/model/order
Place of Origin:
guangzhou,china
Brand Name:
oem/odm/vkin/utl
Size:
can be customized
Payment by:
30%t/t in advance, 70% t/t before shipment
Delivery time:
within 40 days after 30% t/t in advance received
MOQ:
1x40'hq/model/order
Place of Origin:
guangzhou,china
Supplier Info.
Registration Date: 2008
Country / Region: guangdong / China
City: guangzhou
Main Products: air handler heat pump air conditioner, inverter heat pump, heat pump manufacturers
Product Detail
/  Product Features

DC INVERTER INTEGRATED Heat Pumps for HeatingCooling


DC INVERTER INTEGRATED Heat Pumps for HeatingCoolin utilize advanced heat pump technology to achieve high efficiency  with  With the application of DC inverter technology, these series of units can adjust the output capacity automatically and control the room temperature accurately. The intelligent control system means everyone in the family can control the unit. Due to the monobloc design, the units are cost effective, space saving and quiet to run outside.  All of these features work together to give you a more comfortable home.


/  Product Features
undefined

Energy Saving up to 20%-40%

With the use of inverter compressors, brushless DC fan motors and PFC control method, the units can regulate the running capacity . With no frequent start-ups and stop runnings, the units work in stable condition with high efficiency. The energy consumption is 20-40% less than that of standard heat pump units.



undefined

0.5 oC Precise Control

The units can change the operating frequency of the compressors automatically according to the heating or cooling demand. When the target temperature is reached, the units run at a lower frequency, and the temperature control accuracy can be as precise as 0.5oC. high temperature control


undefined

Speed up Heating/Cooling Time

When there is a large difference between the actual temperature and the programmed temperature, the unit can run at a higher frequency to make fast heating or cooling to increase or decrease the temperature rapidly. speed up heating cooling

undefined
Traditional Defrosting Method

Traditional defrosting method is with fixed defrosting time and start temperature . Once the ambient temperature reaches or is lower than -7oC, the unit will start defrosting. It's easy to cause energy wasting when there is no defrost and will reduce the heating performance at the same time.

undefined
Intelligent Defrosting Method

intelligent defrosting uses pressure sliding defrosting technology to figure out the exact defrosting time and start pressure according to the real ambient temperature. It saves energy and makes the heat pump work in high efficiency.intelligent defrosting No frosting in the bottom With the use of the special liquid distribution technology, in heating mode, the temperature of refrigerant in the air exchanger’s bottom copper tube will not decrease in order to ensure no frosting on it and smooth drainage.

undefined
Wire Controller

VKIN self-developed wire controller with glass panel and touch screen can be installed on the wall inside the house. It provides you a convenient way to control the heat pump and is applicable to RS485 communication.

undefined
Core Component

The use of the famous and reliable brand compressor ensures the unit working in the perfect performance..

/  Product parameters
ModelVRHA-48AN1DC/AIOVRHA-60AN1DC/AIOVRHA-100AN1DC/AIO
Input PowePh-V-Hz1,230V,60HZ3,380,50HZ

Rated hot water 

conditions

Heating capacitykW15.60(6.80-17.00)18.00(9.00-19.50)32.00(15.00-35.00)
InputkW3.51(1.65-6.50)4.11(2.1-7.0)7.41(4.38-10.5)
Rated current A16.00(7.51-30.0)18.70(9.54-32.0)11.25(6.65-15.95)X3
COPW/W4.454.384.32

Nominal refrigeration 

conditions

Cooling capacitykW12.30(6.00-14.00)14.85(8.20-16.15)25.00(13.00-27.50)
InputkW4.51(1.78-6.50)5.46(2.28-7.0)9.26(4.65-11.50)
Rated current A20.48(8.09-30.0)24.82(10.36-32.0)14.03(7.06-17.47)X3
EERW/W2.732.722.70 

Nominal heating 

conditions

Heating capacitykW15.0(6.80-16.10)17.00(8.00-18.20)30.00(13.00-33.00)
InputkW4.40(1.65-6.50)4.91(2.0-7.0)8.77(4.20-10.5)
Rated current A20.0(7.51-30.0)22.33(9.09-32.0)13.3(6.36-15.95)X3
COPW/W3.413.463.42

Low temperature 

heating conditions

Heating capacitykW9.510.5  18.50
InputkW3.894.297.55
Rated current A17.7019.4011.44x3
COPW/W2.442.462.45

Ultra - low temperature

heating conditions

Heating capacitykW6.907.7113.21
InputkW3.694.127023
Rated current A16.8018.7510.65x3
COPW/W1.871.871.88
Unit sizelong * wide * highmm1115X425X12621115X425X12621550X510X1720
net weightkg132.5145189
Out of the water pipe sizeDN252540
Noise leveldB≤64≤64≤66
Max Discharging pressureMPa4.24.24.2
Cooling water range5 - 30
Heating water range20 - 60
Ambient temp-25 - 43
Water side resistancekPa404565
Water flow Volumem³/h2.152.584.3
Refrigerant
R410A
Ambient temp-25 - 43

Rated hot water conditions: outdoor dry bulb temperature / outdoor wet bulb temperature 

20/5 ℃ water temperature: 15 ℃ water temperature: 55 ℃

Nominal cooling conditions: outdoor dry bulb temperature / outdoor wet bulb temperature 

35/24 ℃ water temperature: 12 ℃ water temperature: 7 ℃

Nominal heating conditions: outdoor dry bulb temperature / outdoor wet bulb temperature 

7/6 ℃ water temperature: 40 ℃ water temperature: 45 ℃

Low temperature heating conditions: outdoor dry bulb temperature / outdoor wet bulb temperature 

-12 / -14 ℃ water temperature: 36 ℃ water temperature: 41 ℃

Ultra-low temperature heating conditions: outdoor dry bulb temperature / outdoor wet bulb temperature 

-20 / -21 ℃ water temperature: 36 ℃ water temperature: 41 ℃


Contact

Supplier

Contact us
Tell us your Buying Requirements