Main features 2.The voltage of the power supply is 24VDC-36VDC. 3.Having the functions of the current outputted in a half automatically,OVP and ORP. 4.Operating current is 1A-4.2A/phase,the current resolution is 0.45A. 5.There are 15 kinds of subdivision number,the maximum is 25000pulse/rev. 6.With excellent stability ,for control signals and internal signals are photoelectrically.insulated |
Setting the switch of DIP ON=1 OFF=0
The options of the motor subdivision times | The options of the rated current | ||||||||||
SW | Subdivision times | SW | Subdivision times | SW | Subdivision times | SW | Subdivision times | SW | Rated current | SW | Rated current |
1111 | 1 | 1101 | 16 | 1110 | 5 | 1100 | 40 | 111 | 1.0 | 110 | 2.84 |
0111 | 2 | 0101 | 32 | 0110 | 10 | 0100 | 50 | 011 | 1.46 | 010 | 3.31 |
1011 | 4 | 1001 | 64 | 1010 | 20 | 1000 | 100 | 101 | 1.91 | 100 | 3.76 |
0011 | 8 | 0001 | 128 | 0010 | 25 | 0000 | 125 | 001 | 2.37 | 000 | 4.20 |
VDC,GND | VDC,GNDDC power ﹢24V-36V |
A﹢,A- | The motor phase A |
B﹢,B- | The motor phase B |
PUL﹢,PUL- | The positive and negative ends of pulses |
ENA﹢,ENA- | The positive and negative ends of enable signals |
DIR﹢,DIR- | The positive and negative ends of Dir control signals |
Connection Schematic drawing and installation size(unit:mm)
Contact
Supplier