Main features 2.The voltage of the power supply is 24VDC-45VDC. 3.Having the functions of the current outputted in a half automatically,OVP and ORP. 4.Operating current is 0A-5A/phase,the current resolution is 0.4A. 5.There are 22 kinds of subdivision number,the maximum is 40000pulse/rev. |
Setting The Switch Of DIP ON=1 OFF=0
The options of the motor subdivision times | The options of the rated current | ||||||||
SW | Subdivision times | SW | Subdivision times | SW | Subdivision times | SW | Rated current | SW | Rated current |
00001 | 2 | 01001 | 18 | 10001 | 60 | 0001 | 0.4 | 1001 | 3.0 |
00010 | 4 | 01010 | 20 | 10010 | 64 | 0010 | 0.7 | 1010 | 3.3 |
00011 | 5 | 01011 | 25 | 10011 | 72 | 0011 | 1.1 | 1011 | 3.7 |
00100 | 8 | 01100 | 30 | 10100 | 100 | 0100 | 1.3 | 1100 | 3.9 |
00101 | 9 | 01101 | 32 | 10101 | 128 | 0101 | 1.7 | 1101 | 4.3 |
00110 | 10 | 01110 | 36 | 10110 | 200 | 0110 | 2.0 | 1110 | 4.6 |
00111 | 15 | 01111 | 40 | 11111 | test | 0111 | 2.4 | 1111 | 5.0 |
01000 | 16 | 10000 | 50 | 10000 | cw/ccw | 1000 | 2.6 |
|
VDC,GND | VDC,GNDDC power ﹢24V-45V |
A﹢,A- | The motor phase A |
B﹢,B- | The motor phase B |
PUL﹢,PUL- | The positive and negative ends of pulses |
ENA﹢,ENA- | The positive and negative ends of enable signals |
DIR﹢,DIR- | The positive and negative ends of Dir control signals |
SW6 | The function of Auctomatical half current ON=1 OFF=0 |
Connection Schematic Drawing And Installation(unit:mm)