Fire Suppression Engineering Solution
Shenzhen Smartnoble Inc. is a professional fire extinguishing system design, production and sale of Fire fighting company.
HFC-227ea fire fighting system is widely used in China and other parts of the world. FM200 fire extinguishing agent is a colorless and odorless gas. It has zero potential consumption potential for ozone group, meets environmental protection requirements, and has the characteristics of cleanness, low toxicity, good electrical insulation and high fire extinguishing efficiency. It is an ideal substitute for halogenated alkane fire extinguishing agents.
HFC-227ea gas fire suppression system has the advantages of complete design, perfect function, reliable work, long-term storage without leakage, simple installation and debugging, convenient operation and maintenance. The system is mainly composed of automatic alarm controller, storage device, valve drive device, selector valve, check valve, signal feedback device, frame, nozzle, pipe network and other components. According to the requirements of use, it can form a unit independent system and a combined distribution system, and implement fire protection for single-zone and multi-zone respectively. It is mainly used for fire protection of electronic computer room communication center, underground engineering, marine oil only, library, archives, treasures, power distribution rooms and other important places.
We can support the whole fire suppression engineering, including design, installation and fire fighting product. We are your most faithful partners. Welcome to inquiry us.
Fire Fighting Brass Valve
++
Type | Capacity | Max. Working Pressure | Max. Filling Density | Spraying Time | Driveing Mode |
SN5.6/70N | 70L | 5.3MPa
| ≤950kg/m³ | ≤10s | Soleniod or Manual |
SN5.6/100N | 100L |
SN5.6/120N | 120L |
SN5.6/150N | 150L |
SN5.6/180N
| 180L |
SN5.6/200N | 200L |
Application:
1.Electric power construction fire engineering
2.Petroleum, chemical enterprise fire engineering
3.Road traffic fire engineering
4.Heavy industry fire protection engineering
5.Urban traffic fire engineering
6.Enterprise, public institution fire engineering
7.Electric power enterprise fire engineering
8.Subway fire engineering
9.Pier fire engineering
10.Commercial residential fire engineering
11.Civil aviation fire engineering
A. Fire extinguishing systems should be lightly loaded and lightly unloaded during transportation. Collision, lying or inversion are strictly prohibited.
B. Fire extinguishing agent storage bottles and starter bottles should avoid approaching heat sources, prevent direct sunshine, and maintain good dryness and ventilation.
C. In the process of disassembly and assembly, it should be avoided to touch the surface of the device and affect its appearance.
D. Irrelevant personnel are prohibited from touching the parts of the system in order to avoid accidents.
E. Personnel who install and debug the system should be familiar with the basic structure, working principle, performance and operation procedures of the system, as well as the basic structure and working state of each component.
F. Daily maintenance and maintenance should strictly follow the operating procedures to prevent misuse of fire extinguishers.
G. The air in the protective zone should not contain harmful substances of flammable, conductive dust and corrosive parts of Egypt. Otherwise, it must be protected and the system should not be shaken and impacted.
Before spraying extinguishing agent in H. system, all personnel must evacuate the fire scene within a delay period (0-30S adjustable). After extinguishing the fire, the fan must be started first, and the exhaust gas can be discharged before the personnel can enter the scene.
I. Other security measures should follow the relevant national norms.
By sea
Large transportation volume and low cost
By air
Fast speed and safety
By rail
High speed and low cost