Two-Stage Evaporation
System ( IDEC )
Capacity :1TR - 45TR(3KW - 160KW)
Parameter | ||
Model | IDEC -5000 | |
Power Supply | 3N~, 380V 50/60Hz | |
Cooling Capacity | Ton | 12.5 |
Air Flow | CFM | 5000(8500m3/h) |
Rated Input Power | KW | 3.40 |
Rated Input Current | A | 6.1 |
Exteranl Static Pressure | Pa | 120 |
Water Pressure | Mpa | 0.2~0.6 |
Water Gap Spec | inch | 1" |
Noise | dB(A) | ≤80 |
Protection Grade | Ⅱ | |
Waterproof Class | IP×4 | |
Net Weight | kg | 500 |
Gross Weight | kg | 500 |
Net Dimension(L×W×H) | mm | 1690×2283×1314 |
Packing Dimension(L×W×H) | mm | 1750×2343×1474 |
The Ultimate Cooling of the Hicool Desert Greenhouse
◪In the 21st century, Hicool utilized two-stage unique combination of indirect/direct evaporative cooling (IDEC).
◪Our IDEC unit includes first stage indirect heat exchanger and second stage direct evaporative cooling.
◪Hicool making it push the boundaries to create the most advanced two stages indirect / direct (IDEC) air conditioners and deliver 100% fresh air cooling.
◪Combine Optical&Humidity induction control system to create the most advanced Two-Stage Evaporation System ( IDEC ) and deliver 100% fresh air cooling.
◪Achieve the most practical and highest performance evaporative cooling system(EER>10).
Through Hicool high precision Humidity and temperature control sensor, we can know the indoor temperature, humidity and luminosity in real time.
Traditionally, evaporative cooling systems design and the results thereof have been uncertain and have therefore restricted the adoption of this low energy cooling technology.
For the first time,our unique performance predicting software enables engineers to professionally design evaporative cooling systems with complete confidence and certainty.
We are able to consider any project, anywhere in the world, to determine project requirements and accurately predict system performance, energy consumption and the subsequent energy savings the IDEC system will deliver.
Through the comprehensive application of temperature and humidity system, CO2 supply system, ventilation system and computer control system, real-time and precise control is realized, which provides the best growth environment for plants.
During the first stage, the primary outdoor air is blown through a highly effective chilled water heat exchanger without adding moisture, this is the indirect evaporative cooling stage.
During the second stage, the pre-cooled air is then blown through a water saturated media and cooled further by evaporation,this is the direct evaporative cooling stage.
The combination of these two stages delivers the highest performing evaporative cooling system in the world today.
Contact
Supplier
Agriculture Machinery & Equipment
Apparel & Textile Machinery
Building Material Machinery
Chemical Machinery & Equipment
Energy & Mineral Equipment
Engineering & Construction Machinery
Food & Beverage Machinery
Home Product Making Machinery
Industry Laser Equipment
Machine Tool Equipment
Metal & Metallurgy Machinery
Other Machinery & Industry Equipment
Packaging Machine
Paper Production Machinery
Plastic & Rubber Machinery
Printing Machine
Woodworking Machinery
Environmental Machinery
Machinery Accessories
Material Handling Equipment
Welding Equipment
Cleaning Equipments
Commercial Machinery
Air-Compressors & Parts