Air Volume::
3950-72860 m³/h
Air Pressure::
115-480pa
Inlet & Outlet Diameter::
500mm-1500mm
Motor Location::
1.1-15kw
Motor::
single speed
Model No.::
5#, 5.5#,6#,6.5#,7#,8#,9#,10#,11#,12#,13#, 15#。
Min.Order Qty::
1 set
Supply Ability::
5000pcs per month.
Name::
htf(gyf)-d series low speed low pressure fire control axial flow fan
item NO::
htf(gyf)-d
Air Volume::
3950-72860 m³/h
Air Pressure::
115-480pa
Inlet & Outlet Diameter::
500mm-1500mm
Motor Location::
1.1-15kw
Motor::
single speed
Model No.::
5#, 5.5#,6#,6.5#,7#,8#,9#,10#,11#,12#,13#, 15#。
Min.Order Qty::
1 set
Supply Ability::
5000pcs per month.
Product Detail

Low speed low pressure fire-control axial flow fan specifications

 

 Features:
1.  High temperature resistant 
2.  Beautiful appearance 
3.  Widely use 
4.  Easy to install 
5.  Inside box and outside box original design of stiffener, tube axial fans    sturdy and durable.

Low speed low pressure fire-control axial flow fan description:

HTF-D series single speed fire-control axial fan is used for fire control, smoke extraction and ventilation in fire control required constructions such as metro, tunnel, gym, high-rise building, underground store, workshop and oven, usually is equipped with double speed motor, in normal time, the motor runs at low speed for ventilation, once fire happens, the motor will be changed for high speed operating automatically through electric control system and remove the smoke rapidly within half an hour, make the staffs have enough time to withdraw from the fire ground safely to protect the people' s live and property effectively. the translated medium is air, other non hypergolic air, non corrosion air or the air harmless to the human body, dust and solid impurities containing index should be below 150mg/m3. The fan is used for ventilation, the temperature of air inlet should be below 80°C; Used for fire control, the fan can be running continually for more than 30 minutes when fire happen and the temperature of smoke reaches 280°C.


Fire-control axial flow fan technical Parameter:

HTF(GYF)-D 低速低压消防高温排烟轴流风机性能参数表.jpg



The frequency and voltage could be customized.

Packing: plywood case.

Composition: 100% copper wiring motor, high quality wild metal plate basing.


Low speed low pressure fire-control axial flow fan outside box size:

HTF(GYF)-D 低速低压消防高温排烟轴流风机外形尺寸表.jpg


Our service:

Before-sale services:   

(1) Tell customers how to use our products and matters needing attention.

 (2) Guide customers to choose the best and economic product, recover the investment within short time.  

 (3) Site inspection if you need. 

 

In-Sale services:   

(1) Quality control must be inspected strictly.  

(2) In accordance with the agreements stipulated in the contract.   

 

After-sale services:   

(1) If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with 

our product.  

(2) Usually, our product warranty is 18 months after leaving factory or 12 months after installation. Within this months, all parts broken will be responsible for our factory.

(3) Regular contact with customer, consult with the customer feedback, come true with 

the customer's two-way communication.




 

Contact

Supplier

Contact us
Tell us your Buying Requirements