Products Info
HOME> HTF(GYF) Series double speed fire control axial flow fan/ tube axial flow fans >
HTF(GYF) Series double speed fire control axial flow fan/ tube axial flow fans

HTF(GYF) Series double speed fire control axial flow fan/ tube axial flow fans

Name::
htf(gyf) series double speed fire control axial flow fan/ tube axial flow fans
item NO::
htf(gyf)-Ⅱ
Air Volume::
3410-93800 m³/h
Air Pressure::
100-819pa
Inlet & Outlet Diameter::
500-1500mm
Motor Location::
inside tube with cooling system
Motor::
double speed
Model No.::
5#,5.5#,6#,6.3#,6.5#,7#,8#,9#,10#,11#,12#,13#,14#,15#。
Min.Order Qty::
1 set
Supply Ability::
5000pcs per month
Name::
htf(gyf) series double speed fire control axial flow fan/ tube axial flow fans
item NO::
htf(gyf)-Ⅱ
Air Volume::
3410-93800 m³/h
Air Pressure::
100-819pa
Inlet & Outlet Diameter::
500-1500mm
Motor Location::
inside tube with cooling system
Motor::
double speed
Model No.::
5#,5.5#,6#,6.3#,6.5#,7#,8#,9#,10#,11#,12#,13#,14#,15#。
Min.Order Qty::
1 set
Supply Ability::
5000pcs per month
Product Detail

Fire-control axial flow fan specifications

 

 Features:
1.  High temperature resistant 
2.  Beautiful appearance 
3.  Widely use 
4.  Easy to install 

Fire-control tube axial flow fans description:

HTF-III series single speed fire-control axial fan is used for fire control, smoke extraction and ventilation in fire control required constructions such as metro, tunnel, gym, high-rise building, underground store, workshop and oven, usually is equipped with double speed motor, in normal time, the motor runs at low speed for ventilation, once fire happens, the motor will be changed for high speed operating automatically through electric control system and remove the smoke rapidly within half an hour, make the staffs have enough time to withdraw from the fire ground safely to protect the people' s live and property effectively. the translated medium is air, other non hypergolic air, non corrosion air or the air harmless to the human body, dust and solid impurities containing index should be below 150mg/m3. The fan is used for ventilation, the temperature of air inlet should be below 80°C; Used for fire control, the fan can be running continually for more than 30 minutes when fire happen and the temperature of smoke reaches 280°C.


Fire-control axial flow fan technical Parameter:



Model No.

The Inlet & Outlet Diameter

Air Volume

Pressure

Revolution

Power

The actualpower

A Noise Level

mm

m³/h

Pa

rpm

KW

KW

dB(A)

5

500

9824

510

2900

3/2.5

2.5/0.3

≤86

8861

610

6817

752

4912

127

1450

≤75

4431

153

3410

188

5.5

550

15200

398

2900

4/3.3

3.1/0.39

≤86

12000

592

10900

621

7600

100

1450

≤75

6000

148

5450

155

6

600

16090

510

2900

5.5/4.5

4.7/0.6

≤86

15102

610

13197

760

8045

127

1450

≤75

7551

153

6599

190

6.5

650

21500

425

1450

5.5/4

5.1/1.5

≤88

18000

620

15300

680

14235

187

960

≤80

11918

272

10130

298

7

700

24380

610

1450

8/6.5

7/2

≤88

22439

655

18908

728

16141

267

960

≤80

14865

287

12518

319

8

800

31421

600

1450

8/6.5

7.1/4.1

≤89

29172

661

26012

723

20800

263

960

≤80

19314

290

17222

317

9

900

33510

562

1450

11/9

10.4/6.8

≤90

32297

668

27613

840

22186

246

960

≤81

21383

293

18216

368

10

1000

45679

630

1450

11/9

10.5/6.9

≤90

40000

690

35000

770

30255

276

960

≤80

26483

302

24019

338

11

1100

51552

580

1450

16/13

14.5/6.1

≤92

50128

647

48500

690

38664

326

960

≤83

37596

364

36375

387

12

1200

62763

624

960

17/8

15/6.3

≤93

59300

680

57748

740

47072

351

720

≤83.5

44475

385

43311

416

13

1300

74708

600

960

17/8

15/6.3

≤94

65370

710

56031

807

56031

338

720

≤84.5

49027

399

42023

454

15

1500

93800

623

960

22/11

20/8.5

≤95

86115

710

76041

819

70350

350

720

≤85

64586

410

57031

461


The frequency and voltage could be customized.

Packing: plywood case.

Composition: 100% copper wiring motor, high quality wild metal plate basing.

 

Fire-control axial flow fan model instructions:

HTF 高温排烟轴流风机 型号说明.jpg


Fire-control tube axial flow fan outside box size:

HTF-Ⅲ 单速消防高温排烟轴流风机外形尺寸表.jpg


Our service:

Before-sale services:   

(1) Tell customers how to use our products and matters needing attention.

 (2) Guide customers to choose the best and economic product, recover the investment within short time.  

 (3) Site inspection if you need. 

 

In-Sale services:   

(1) Quality control must be inspected strictly.  

(2) In accordance with the agreements stipulated in the contract.   

 

After-sale services:   

(1) If the project needs our installation guidance, we can send our engineer and translator. We can also send customers installation video to teach them how to fix and operate with 

our product.  

(2) Usually, our product warranty is 18 months after leaving factory or 12 months after installation. Within this months, all parts broken will be responsible for our factory.

(3) Regular contact with customer, consult with the customer feedback, come true with 

the customer's two-way communication.

 


Contact

Supplier

Contact us
Tell us your Buying Requirements