Products Info
HOME> Electrical Equipment & Supplies > Industrial Controls > Oil immersed power transformer with conservator 10kva/10kv or above with IEC/ISO9001 certificate >
Oil immersed power transformer with conservator 10kva/10kv or above with IEC/ISO9001 certificate

Oil immersed power transformer with conservator 10kva/10kv or above with IEC/ISO9001 certificate

Brand Name:
langteng
Place Of Origin:
china
Model Number:
sbh15-m
Material:
copper /aluminum
Certification:
iso9001\iec
Availability:
odm and oem
Delivery Time:
30-60 days
Start Port:
foshan
Supply Ability:
about 12,000 pcs/year
MOQ:
none
Payment Terms:
l/c,t/t
Altitude:
≤2000m
Ambient temperature:
≥-45℃
Brand Name:
langteng
Place Of Origin:
china
Model Number:
sbh15-m
Material:
copper /aluminum
Certification:
iso9001\iec
Availability:
odm and oem
Delivery Time:
30-60 days
Start Port:
foshan
Supply Ability:
about 12,000 pcs/year
MOQ:
none
Payment Terms:
l/c,t/t
Altitude:
≤2000m
Ambient temperature:
≥-45℃
Supplier Info.
Registration Date: 2007
Country / Region: guangdong / China
City: foshan
Main Products: line reactor,transformer company,reactor
Product Detail
Product introduction

Oil conservators(also known as oil reservoirs)are cylindrical containers. The volume of the oil conservator is generally about 10% of the oil volume of tank. The oil conservator is mounted on the fuel tank, connected with the oil tank by a curved connecting pipe. When the volume of transformer oil expands or shrinks with the change of oil temperature, the oil conservator acts as oil storage and replenishment to ensure that the oil tank is filled. Since the spare position of the oil conservator is small, reducing the contact area between oil and air as well as the moisture, and the speed of oil damp and oxidation is reduced. Oil conservators of large capacity transformers also use nitrogen and diaphragm to isolate the oil and the air contact, preventing its damp aging. The oil in the oil conservator is lower than the oil in the upper part of the tank, and the oil in the tank is hardly convection.

The oil in conservators should be kept at a certain limit to ensure that oil expands and shrinks at different temperatures with certain leeway. An oil-level indicator which is usually a glass tube or ferromagnetic is arranged at one end of the oil conservator, to observe the level of the oil surface. The bottom of the oil pillow is a deposit container used to sink the mechanical impurities, water and dirt immersed in the transformer oil.  They will be regularly drained out through the drain valve.

undefined

Usage environment
  • Altitude
    ≤ 1000 meters.
  • Ambient temperature
    ≤40 ℃
  • Maximum monthly average air temperature
    30 ℃
  • Maximum yearly average air temperature
    20 ℃
  • Minimum temperature
    -45℃ (applicable to outdoor)
  • Minimum temperature
    -5 ℃ (applicable to indoor)
  • Electric wave form
    approximate sine wave
  • Relative Humidity
    daily average ≤ 95%, monthly average≤ 90%
  • Installation area
    can be installed both outdoor and indoor.
  • Voltage Frequency
    50/60Hz
Technical parameters
S11    series  30-1600KVA
10KV Technical parameters of    dual-wingdings no excitation regulation power transformers
Rated
capacity
KVA&tapping range Connection
series
 number
No-load lossLoad loss No-load
current%
Impedance
voltage%
KVAHigh
voltage KV
Tapping
range of
high
voltage %
Low voltage
     KV
KWKW
30

±5%
or
±2×5%

0.4

Dyn11
Yzn11
 Yyn0

1000.63/0.602.1

4

50
1300.91/0.872
80
1801.31/1.251.8
100
2001.58/1.81.6
125
2401.89/1.81.5
16062702.31/2.21.4
2006.33302.73/2.61.3
250104003.2/3.051.2
31510.54803.83/3.651.1
400115704.52/4.31
500
6805.41/5.151
630
8106.20.9

4.5

800
9807.50.8
1000

Dyn11
Yyn0

115010.30.7
1250
1360120.6
1600
164014.50.6