Product: | BVR Solid Cable(ZR-BVR) | Standard: | IEC |
Brand: | Asia Port | Construction: | Plain annealed copper, PVC insulated cable |
Cores Number: | Single core | Conductor Material: | OFC(copper content: 99.99%) |
Operating temperature: | 70℃ | Insulation Material: | PVC |
Nominal Voltage: | 0.6/1kV | ||
Colors: | Red、 Yellow、 Blue、Green、 Black、 Yellow\Green or as per order |
Application This cable is suitable for AC rated voltage 450 / 750V and below, requiring flame occasions electrician, instrumentation, telecommunications equipment, power equipment and lighting circuit fixed laying. | |
Cables Features All models of the cable’s long-term allowable working temperature should not exceed 70℃. Cable laying temperature should not below 0℃, the outer diameter (D) should be less than 25mm, cable bending radius should be not less than 4D, the outer diameter (D) of cable allowable bending radius 25mm and above should be not less than 6D. |
Chat >>
Both BVR wire’ insulation material and the sheath material are PVC. According to different performances, this cable can be classified into three types: ordinary cable, flame-retardant cable, fire-resistant cable.
Models | Cables | Cores Number | Nominal Cross Section (mm²) | Usage |
BVR | Copper Core PVC Insulated Flexible Wire | Power , electrical instrumentation and automation equipment | ||
ZR-BVR | Flame retardant copper core PVC insulated flexible wires | requiring flame occasions electrician , instrumentation, telecommunications equipment, power equipment and lighting circuit fixed laying. | ||
NH-BVR | Refractory copper core PVC insulated flexible wire | Control and monitor circuits , power, line protection and other occasions as well as large-scale construction, petroleum, metallurgy, chemicals, cables, ships, crowded places and other places where it is needed a high fire-retardant and fire-resistant cables. |
nominal cross section (mm²) | Insulation Nominal thickness(mm) | Mean Outside Diameter Upper Limit(mm) | 20℃ insulation resistance MΩ.km | 70℃ insulation resistance MΩ.km | |
Copper Core | Tin plated copper Core | ||||
0.75 | 7 | 2.9 | 24.5 | 24.8 | 0.013 |
1.0 | 7 | 3.1 | 18.1 | 18.2 | 0.012 |
1.5 | 7 | 3.4 | 12.1 | 12.2 | 0.011 |
2.5 | 19 | 4.1 | 7.41 | 7.56 | 0.011 |
4 | 19 | 4.8 | 4.61 | 4.70 | 0.009 |
6 | 19 | 5.3 | 3.08 | 3.11 | 0.0084 |
10 | 49 | 1.0 | 1.83 | 1.84 | 0.0072 |
16 | 49 | 1.0 | 1.15 | 1.16 | 0.0062 |
25 | 98 | 1.2 | 0.727 | 0.734 | 0.0058 |
35 | 133 | 1.2 | 0.524 | 0.529 | 0.0052 |
50 | 133 | 1.4 | 0.387 | 0.391 | 0.0051 |
70 | 189 | 1.4 | 0.268 | 0.270 | 0.0045 |
95 | 259 | 1.6 | 0.193 | 0.195 | 0.0044 |
120 | 259 | 1.6 | 0.153 | 0.154 | 0.0040 |
150 | 336 | 1.8 | 0.124 | 0.126 | 0.0040 |
185 | 427 | 2.0 | 0.0991 | 0.100 | 0.0040 |
P.S. NH-BVV, ZR-BVV and BVV are in the same series, so all of the structure specifications diameters are the same. |