SL-031 ESD Wrist and Foot Strap Tester
1.Simple operation with dual test circuits.
2.tests both wrist straps and foot grounder
Simple operation with dual test circuits, tests both wrist straps and foot grounders. Auto-ranging circuit automatically selects proper test range, user touches pad and LED displays test results. Red light and audible indicator mean circuit resistance is too high or too low. It is complied with standard 6.1.3.2 in ANSI ESD S20.20.
Specification
Operating Temperature | 0~31 degree |
Relative Humidity | 0~90% |
Size | Instrument: 142.5(L)×82(W)×39(H); support: 400(L)×250(W)×800(H); footboard: 400(L)×450(W);) |
Weight | 235g |
Measuring instrument altitude mixture control scope | 900mm-1470mm |
Decay Test Results
Wrist test margin : 750KΩ-10.5MΩ | Shoe cover test margin , 750KΩ-100MΩ | ||
Resistance tolerance (±20%) | Test output | Resistance tolerance (±20%) | Test output |
≤ 740K Ω | Red (FAIL LO ) | ≤ 740K Ω | Red (FAIL LO )) |
750KΩ | Green (PASS (Normal )) | 750KΩ | Green (PASS (Normal )) |
10. 5MΩ | Green (PASS (Normal )) | 100MΩ | Green (PASS (Normal )) |
≥ 11.5M Ω | Red (FAIL HI (Fail Hi )) | ≥ 40M Ω | Red (FAIL HI (Fail Hi )) |