These equipment are placed in a false ceiling where most of the unit is hiden. The 4 ways cassettes vacuum the air via the central grille and expel it (hot or cold) into the room via the 4 outputs.
These equipment are placed in a false ceiling where most of the unit is hiden. The 4 ways cassettes vacuum the air via the central grille and expel it (hot or cold) into the room via the 4 outputs.
The comfort temperature is veru quickly obtained evenly in the room due to the 4 outputs.
the fan blade has an irregular propeller design, internal unit can work at a lower noise level
The grille may be removed to access internal parts without having to remove from the ceiling.from the frontal panel you can easily access to the filters to clean them periodically or to substitute them.Central intake grille with filter to guarantee clean air.
The cassette provides a versatile solution for a wide range of commercial, retail and leisure applications where maintaining comfortable temperature control of the environment is essential.
a ceiling cassette consists of two parts, an outdoor condensing unit and an indoor air handler connected by refrigerant and electrical lines that run through a 3" opening in an exterior wall. This system requires a licensed HVAC technician to connect the lines between the indoor and outdoor components.
R410A DC INVERTER FOUR-WAY CASSETTE TYPE AIR CONDITIONER | ||||||||
Model | UCHA-12CDC | UCHA-18CDC | UCHA-24CDC | UCHA-36CDC | UCHA-48CDC | UCHA-60CDC | ||
Power supply | Ph-V-Hz | 1, 230V, 60Hz | 1, 230V, 60Hz | |||||
3, 380~415V, 60Hz | ||||||||
Cooling | Capacity | BTU | 11940(3200-13640) | 17400(8180-20130) | 23880(11600-29000) | 35820(14110-40000) | 48100(21150-51860) | 59020(27970-64140) |
Input | W | 955(270-1550) | 1448(750-2200) | 2177(1300-3450) | 3357(2100-4350) | 4752(2500-4950) | 5962(2600-6500) | |
Rated current | A | 4.4(1.5~6.75) | 6.5(3.4~10.0) | 9.3(6.0~16.0) | 14.9(9.5-18.9) | 20.8(11.6-22.5) | 26.0(12.1-28.9) | |
EER | BTU/W | 12.48 | 12.11 | 11.87 | 11.42 | 11.12 | 10.57 | |
Heating | Capacity | BTU | 12960(3350-15350) | 18420(8520-50930) | 2520012960-31730) | 37870(20470-42650) | 49850(23030-54590) | 61400(30700-66530) |
Input | W | 1179(260-1580) | 1694(675-2280) | 2380(1310-3600) | 3620(2400-4600) | 4998(2050-5600) | 6338(2780-6800) | |
Rated current | A | 5.1(1.5-7.35) | 7.4(3.5-11.2) | 9.8(6.1-16.3) | 15.9(10.4-20.5) | 21.6(8.9-24.8) | 27.2(12.9-29.5) | |
COP | BTU/W | 11.29 | 11.08 | 10.84 | 10.61 | 10.30 | 10.20 | |
SEER | BTU·h/W·h | 20.19 | 18.12 | 17.89 | 16.98 | 15.89 | 14.79 | |
Indoor air flow | CFM | 400 | 447 | 500 | 617 | 815 | 945 | |
Indoor unit | Dimension (W*H*D) | Inch | 22.6×22.6×11.3 | 22.6×22.6×11.3 | 27.7×27.7×11.3 | 32.5×32.5×11.3 | 32.5×32.5×11.3 | 37.4×37.4×11.3 |
Packing (W*H*D) | Inch | 23.6×23.6×11.9 | 23.6×23.6×11.9 | 28.5×28.5×11.9 | 33.3×33.3×11.9 | 33.3×33.3×11.9 | 38.2×38.2×11.9 | |
Net/Gross weight | Ibs | 56.2/60.4 | 63.5/69.0 | 76.5/81.0 | 87.7/92.8 | 99.0/104.2 | 112.2/128.0 | |
Outdoor unit | Dimension (W*H*D) | Inch | 31.2X21.5X9.75 | 34.1X24X12.3 | 830X310X710 | 34.3X31.2X14 | 34.3X31.2X14 | 49.5X36.3X15.2 |
Packing (W*H*D) | Inch | 34.7X25.5X14 | 38.2X26.9X15.8 | 38.2X35.5X18.1 | 40.1×17.6×32.6 | 40.1×17.6×32.6 | 50X41.7X19.1 | |
Net/Gross weight | Ibs | 94.5/99.0 | 117.0/121.5 | 148.5/152.8 | 144.3/149.5 | 229.5/249.7 | 239.5/258.5 | |
Noise level | Indoor | dB(A) | 30-42 | 32-46 | 33-48 | 35-48 | 35-50 | 35-52 |
Outdoor | dB(A) | 50 | 52 | 54 | 55 | 58 | 60 | |
Design pressure | Psi | 600 | 600 | 600 | 600 | 600 | 600 | |
MAX FUSE SIZE | A | 15 | 15 | 20 | 25 | 35 | 40 | |
MAX.Pipe Length | Ft | 32.81 | 32.81 | 49.21 | 49.21 | 65.62 | 82.02 | |
MAX.Height Difference | Ft | 26.25 | 26.25 | 32.81 | 32.81 | 49.21 | 49.21 | |
Pipe Size Liquid/Gas | Inch | 1/4 - 1/2 | 1/4 - 1/2 | 3/4 - 5/8 | 3/4 - 5/8 | 1/2 - 3/4 | 1/2 - 3/4 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | R410a | ||
Operation temp | ℉ | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | |
Ambient temp | ℉ | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | -13 - 116 | |
Application area | Ft2 | 151-237 | 210-324 | 486-648 | 810-972 | 1080-1188 | 1188-1350 | |
Compressor | Model | 5RS102ZAA01 | DA130S1C-20FZ | DA150S1C-20FZ | C-7RV153HOW | 5VD420ZAA21 | E405DHD38A2G | |
Type | ROTARY | ROTARY | ROTARY | ROTARY | ROTARY | SCROLL | ||
Brand | MATSUSHITA | GMCC | GMCC | SANYO | MATSUSHITA | HITACHI | ||
Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0℉\75.0℉ Indoor dry bulb temperature/Wet bulb temperature80.0℉\67.0℉ | ||||||||
Rated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0℉\43.0℉ Indoor dry bulb temperature/Wet bulb temperature70.0℉\60.0℉ | ||||||||
The difference between the fixed-frequency and frequency of:: | ||||||||
Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow (19-109 ℉) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot. | ||||||||
Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13-126 ℉) and can change depending on the temperature and adjust the size of the room cooling / heating capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic climate control, power consumption energy-saving effect is remarkable. |
Contact
Supplier