Products Info
HOME> Electrical Equipment & Supplies > Power Supplies > 12V 3A iron shell power supply for industrial equipment >
12V 3A iron shell power supply for industrial equipment

12V 3A iron shell power supply for industrial equipment

MOQ:
1pcs(small quantity is acceptable)
Place of Origin:
shenzhen, china
Payment Terms:
l/c, t/t, westernunion, paypal, cash
Delivery Time:
7-30 working days depends on quantity
OEM/ODM Availability:
yes
Certification:
ccc/fcc/rohs/ce
Warranty:
3 years
Start Port:
shenzhen
MOQ:
1pcs(small quantity is acceptable)
Place of Origin:
shenzhen, china
Payment Terms:
l/c, t/t, westernunion, paypal, cash
Delivery Time:
7-30 working days depends on quantity
OEM/ODM Availability:
yes
Certification:
ccc/fcc/rohs/ce
Warranty:
3 years
Start Port:
shenzhen
Supplier Info.
Registration Date: 2004
Country / Region: guangdong / China
City: huizhou
Main Products: power supply, power adapter, power adapter manufacturer
Product Detail
SYR-20W
MODELAD-S0540AAAD-S09223AAAD-S12167AAAD-S15134AAAD-S24084AAAD-S48042AA
OutputDC Voltage5V9V12V15V24V48V
Rated Current4A2.23A1.67A1.34A0.84A0.42A
Current Range0~4A0~2.23A0~1.67A0~1.34A0~0.84A0~0.42A
Rated Power20W20.07W20.04W20.1W20.16W20.16W
Ripple & Noise Max(Note2)120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p
Voltage Adj. Range±10%±10%±10%±10%±10%±10%
Voltage Tolerance(Note 3)±7%±7%±6%±5%±5%±5%
Line Regulation(Note 4)±0.5%±0.5%±1%±1%±1%±1%
Load Regulation(Note 5)±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Setup/Rise Time1000ms,30ms/220Vac (Full load)
Hold up time(Typ.)100ms/220Vac (Full load)
InputVoltage Range100~240Vac
Frequency Range50/60Hz
Efficiency(Typ.)80%80%85%85%80%80%
Ac Current(Typ.)0.1A/220Vac
Inrush Current(Typ.)Cold Start: 50A/220Vac
Leakage Current(Typ.)3mA
ProtectionOver load protection110%~135%
Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over Voltage protection115%~150%
Protection type: Hiccup mode,recovers automatically after fault condition is removed
Over-temperature protectionProtected Mode: crystal internal contact temperature exceeds 140℃, turn off the output, when the temperature returns to normal automatic recovery
EnvironmentWorking Temp-10℃~60℃(Refer to "derating curve ")
Working Humidity20~90%RH, non-condensing
Storage Temp/Humidity-30℃~75℃ 10~98%RH, non-condensing
Temp Coefficient±0.03%℃(0~50℃)(+5V)
Vibration10Min/1 cycle,period for 60min, each along X, Y, Z axes
Safety & EMC(Note 7)Safety Standards Note 6GB4943, EN60950
Withstand VoltageI/P-O/P: 2.5KVAC  I/P-FG: 1.5KVAC O/P-FG: 1.5KVAC
Isolation ResistanceI/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH
EMI Conduction RadiationCompliance to: EN55022, EN61000-3-2, 3. FCC part15, GB9254 class B, GB17625.1
EMS ImmunityCompliance to: EN61000-4-2, 3, 4, 5, 6, 8, 11, light industry level, criteria A
OthersMBTF≥10000h.
Dimension/Packing89*70*37mm(L*W*H) /0.18KG;100pcs/18Kg
Note1.All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.Line regulation is measured from low line to high line at rated load.
5.Load regulation measurement: from 0% to rated load of 100%.
6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for safe use.
7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation.


SYR-24W
MODELAD-S0548AAAD-S09267AAAD-S1220AAAD-S1516AAAD-S2410AAAD-S4805AA
OutputDC Voltage5V9V12V15V24V48V
Rated Current4.8A2.67A2A1.6A1A0.5A
Current Range0~4.8A0~2.67A0~2A0~1.6A0~1A0~0.5A
Rated Power24W24.03W24W24W24W24W
Ripple & Noise Max(Note2)120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p
Voltage Adj. Range±10%±10%±10%±10%±10%±10%
Voltage Tolerance(Note 3)±7%±7%±6%±5%±5%±5%
Line Regulation(Note 4)±0.5%±0.5%±1%±1%±1%±1%
Load Regulation(Note 5)±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Setup/Rise Time

1000ms,30ms/220Vac (Full load)

Hold up time(Typ.)

100ms/220Vac (Full load)


SYR-36W
MODELAD-S0572AAAD-S0940AAAD-S1230AAAD-S1524AAAD-S2415AAAD-S48075AA
OutputDC Voltage5V9V12V15V24V48V
Rated Current7.2A4A3A2.4A1.5A0.75A
Current Range0~7.2A0~4A0~3A0~2.4A0~1.5A0~0.75A
Rated Power36W36W36W36W36W36W
Ripple & Noise Max(Note2)120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p
Voltage Adj. Range±10%±10%±10%±10%±10%±10%
Voltage Tolerance(Note 3)±7%±7%±6%±5%±5%±5%
Line Regulation(Note 4)±0.5%±0.5%±1%±1%±1%±1%
Load Regulation(Note 5)±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Setup/Rise Time1000ms,30ms/220Vac (Full load)
Hold up time(Typ.)100ms/220Vac (Full load)



SYR-48W
MODELAD-S0596AAAD-S09534AAAD-S1240AAAD-S1532AAAD-S2420AAAD-S4810AA
OutputDC Voltage5V9V12V15V24V48V
Rated Current9.6A5.34A4A3.2A2A1A
Current Range0~9.6A0~5.34A0~4A0~3.2A0~2A0~1A
Rated Power48W48.06W48W48W48W48W
Ripple & Noise Max(Note2)120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p
Voltage Adj. Range±10%±10%±10%±10%±10%±10%
Voltage Tolerance(Note 3)±7%±7%±6%±5%±5%±5%
Line Regulation(Note 4)±0.5%±0.5%±1%±1%±1%±1%
Load Regulation(Note 5)±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Setup/Rise Time1000ms,30ms/220Vac (Full load)
Hold up time(Typ.)100ms/220Vac (Full load)

SYR-60W
MODELAD-S05100AAAD-S09667AAAD-S1250AAAD-S1540AAAD-S2425AAAD-S48125AA
OutputDC Voltage5V9V12V15V24V48V
Rated Current10A6.67A5A4A2.5A1.25A
Current Range0~10A0~2.66A0~5A0~4A0~2.5A0~1.25A
Rated Power50W60.03W60W60W60W60W
Ripple & Noise Max(Note2)120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p120mVp-p
Voltage Adj. Range±10%±10%±10%±10%±10%±10%
Voltage Tolerance(Note 3)±7%±7%±6%±5%±5%±5%
Line Regulation(Note 4)±0.5%±0.5%±1%±1%±1%±1%
Load Regulation(Note 5)±2.0%±1.0%±1.0%±1.0%±1.0%±1.0%
Setup/Rise Time1000ms,30ms/220Vac (Full load)
Hold up time(Typ.)100ms/220Vac (Full load)