ST-200W-Ultra-thin | |||||||
MODEL | AD-S05400AA | ||||||
Output | DC Voltage | 5V | |||||
Rated Current | 40A | ||||||
Current Range | 0~40A | ||||||
Rated Power | 200W | ||||||
Ripple & Noise Max(Note2) | 100mVp-p | ||||||
Voltage Adj. Range | ±10% | ||||||
Voltage Tolerance(Note 3) | ±7% | ||||||
Line Regulation(Note 4) | ±0.5% | ||||||
Load Regulation(Note 5) | ±2.0% | ||||||
Setup/Rise Time | 500ms,30ms/230VAC 1200ms,30ms/180VAC (Full load) | ||||||
Hold up time(Typ.) | 60ms/230VAC 14ms/180VAC(Full load) | ||||||
Input | Voltage Range | 180~240VAC | |||||
Frequency Range | 50/60Hz | ||||||
Efficiency(Typ.) | 80% | ||||||
Ac Current(Typ.) | 9.09A/180VAC 4.5A/220VAC | ||||||
Inrush Current(Typ.) | Cold Start: 42A/240VAC | ||||||
Leakage Current(Typ.) | < 2mA/240VAC | ||||||
Protection | Over load protection | 105%~150% | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over Voltage protection | 115%~150% | ||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over-temperature protection | Protected Mode: crystal internal contact temperature exceeds 140 ℃, turn off the output, when the temperature returns to normal automatic recovery | ||||||
Environment | Working Temp | -10℃~60℃(Refer to "derating curve ") | |||||
Working Humidity | 20~90%RH, non-condensing | ||||||
Storage Temp/Humidity | -30℃~75℃ 10~98%RH, non-condensing | ||||||
Temp Coefficient | ±0.03% ℃(0~50℃)(+5V) | ||||||
Vibration | 10Min/1 cycle,period for 60min,each along X,Y,Z axes | ||||||
Safety & EMC (Note 7) | Safety Standards Note 6 | GB4943, EN60950 | |||||
Withstand Voltage | I/P-O/P: 3KVAC I/P-FG: 1.5KVAC O/P-FG: 1.5KVAC | ||||||
Isolation Resistance | I/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH | ||||||
EMI Conduction Radiation | Compliance to: EN55022, EN61000-3-2,3. FCC part15, GB9254 class B, GB17625.1 | ||||||
EMS Immunity | Compliance to: EN61000-4-2,3,4,5,6,8,11,light industry level, criteria A | ||||||
Others | MBTF | ≥100000h. | |||||
DimensionPacking | 190*80*30mm(L*W*H) /0.75KG;24pcs/18Kg | ||||||
Note | 1.All parameters NOT specially mentioned are measured at 220VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation measurement: from 0% to rated load of 100%. 6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for safe use. 7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation. |