Full DC high performance air conditioning. It is eco-friendly and comfortable to use from large living room to living room in any room, and energy efficient throughout the year.
R410A new refrigerant green air conditioning strong heating
The new refrigerant R410A is currently fluorine-free environmentally friendly refrigerant products, which consists of hydrofluorocarbon, carbon atoms. Also has superior energy transfer effectiveness. Avoiding the damage to the atmospheric ozone layer and slowing down the global warming process, creating a fresh and beautiful environment for our next generation. Meanwhile, it can also improve the cooling capacity, so as to realize the energy-efficient and energy-saving of air conditioners.
Full DC high performance air conditioning. It is eco-friendly and comfortable to use from large living room to living room in any room, and energy efficient throughout the year.
APF is the annual energy consumption efficiency, which is the amount of heat that the air conditioner removes from room air during the cooling season and the sum of the heat that is sent into the room during the heating season and the total amount of electricity consumed over the same period. This number reflects overall energy efficiency, taking into account factors such as operating hours at various outdoor temperatures, changes in capacity and efficiency of the inverter during cooling / heating operations.
Temperature settings will gradually automatically match your sleep time, to achieve both energy-saving and comfortable timer function.
R410A DC INVERTER MINI SPLIT AIR CONDITIONER | |||||||
Model | URHA-09WDC | URHA-12WDC | URHA-18WDC | URHA-24WDC | URHA-36WDC | ||
Power supply | Ph-V-Hz | 1, 230V, 60Hz | |||||
Cooling | Capacity | BTU | 9000(2388-9894) | 11940(3400-13300) | 17600(8180-19100) | 23880(12280-27290) | 35480(17050-40900) |
Input | W | 700(270-1000) | 956(270-1750) | 1470(750-2200) | 2047(1300-3450) | 3260(1350-3800) | |
Rated current | A | 3.0(1.2~4.5) | 4.2(1.5~7.95) | 6.4(3.4~10.0) | 8.9(6.0~16.0) | 14.2(5.86-16.5) | |
EER | BTU/W | 12.65 | 12.48 | 11.97 | 11.66 | 10.88 | |
Heating | Capacity | BTU | 9550(3070-10235) | 12950(3580-15350) | 18600(8400-20300) | 24900(13640-29000) | 37530(22170-41960) |
Input | W | 725(260-1100) | 1030(260-2000) | 1514(675-2280) | 2080(1310-3600) | 3395(1420-3950) | |
Rated current | A | 3.3(1.4-5.0) | 4.7(1.5-9.1) | 6.6(3.5-11.2) | 9.78(6.1-16.36) | 15.11(6.17-17.17) | |
COP | BTU/W | 13.17 | 12.58 | 12.28 | 11.97 | 11.05 | |
SEER | BTU·h/W·h | 24 | 23 | 21 | 17 | 15 | |
Indoor air flow (H/M/L) | CFM | 311/270/205 | 311/270/205 | 352/305/247 | 588/480/376 | 765/665/576 | |
Dehumidification Capacity in Cooling mode | Outdoor ambient temperature: DB95℉(35℃)/WB75℉(23.9℃),RH 40%; Indoor ambient temperature: DB80℉(26.7℃)/WB67℉(19.4℃),RH 51%. | L/H | 0.8 | 1.0 | 1.8 | 2.35 | 2.85 |
Dehumidification Capacity in dehumidification mode | L/H | 0.42 | 0.6 | 0.85 | 1.18 | 1.35 | |
Dehumidification Capacity in Cooling mode | Outdoor ambient temperature: DB81℉(27℃)/WB75℉(24℃),RH 78%; Indoor ambient temperature: DB81℉(27℃)/WB75℉(24℃),RH 78%. | L/H | 1.7 | 2.15 | 3.1 | 4.15 | 5.5 |
Dehumidification Capacity in dehumidification mode | L/H | 1.1 | 1.4 | 2.3 | 3.12 | 3.8 | |
Indoor unit | Dimension (W*H*D) | Inch | 30.4×11.0×6.8 | 30.4×11.0×6.8 | 35.9×10.9×7.8 | 40.8×13.1×9.6 | 49.8×13.2×9.8 |
Packing (W*H*D) | Inch | 33.2×13.1×9 | 33.2×13.1×9 | 38.2×12.7×9.6 | 41.9×14.2×10.7 | 51.5×14.9×11.4 | |
Net/Gross weight | Ibs | 19.1/24.7 | 19.1/24.7 | 23.6/29.2 | 34.2/41.6 | 45.9/52.8 | |
Outdoor unit | Dimension (W*H*D) | Inch | 31.2X21.5X9.8 | 31.2X21.5X9.8 | 34.1X24X12.3 | 32.37X12.1X27.7 | 34.3×14×31.2 |
Packing (W*H*D) | Inch | 34.7X25.5X14 | 34.7X25.5X14 | 38.2X26.9X15.8 | 38.2X35.5X18.1 | 40.1×17.6×32.6 | |
Net/Gross weight | Ibs | 85.5/92.2 | 94.5/101.2 | 117.4/125.5 | 148.5/153.0 | 144.0/150.7 | |
Noise level | Indoor | dB(A) | 30-42 | 30-42 | 32-46 | 33-48 | 35-50 |
Outdoor | dB(A) | 46 | 55 | 58 | 59 | 63 | |
MAX FUSE SIZE | A | 10 | 15 | 15 | 20 | 25 | |
MAX.Pipe Length | Ft | 26.25 | 32.81 | 32.81 | 49.21 | 49.21 | |
MAX.Height Difference | Ft | 16.40 | 26.25 | 26.25 | 32.81 | 32.81 | |
Pipe Size Liquid/Gas | Inch | 1/4 - 3/8 | 1/4 - 1/2 | 1/4 - 1/2 | 3/4 - 5/8 | 3/4 - 5/8 | |
Refrigerant | R410a | R410a | R410a | R410a | R410a | ||
Design pressure | psi | 600 | 600 | 600 | 600 | 600 | |
Operation temp | ℉ | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | 62 - 88 | |
Ambient temp | ℉ | 5 - 110 | 5 - 110 | 5 - 110 | 5 - 110 | 5 - 110 | |
Application area | Ft2 | 108-172 | 151-237 | 216-324 | 324-432 | 402-540 | |
Compressor | Model | DA89X1C-20FZ3 | 5RS102ZAA01 | DA130S1C-20FZ | DA150S1C-20FZ | C-7RV153HOW | |
Type | ROTARY | ROTARY | ROTARY | ROTARY | ROTARY | ||
Brand | GMCC | MATSUSHITA | GMCC | GMCC | SANYO | ||
Rated cooling test conditions:Outdoor dry bulb temperature/Wet bulb temperature95.0℉\75.0℉ Indoor dry bulb temperature/Wet bulb temperature80.0℉\67.0℉ | |||||||
Rated heating test conditions:Outdoor dry bulb temperature/Wet bulb temperature47.0℉\43.0℉ Indoor dry bulb temperature/Wet bulb temperature70.0℉\60.0℉ | |||||||
The difference between the fixed-frequency and frequency of:: | |||||||
Fixed-frequency machine: the outdoor unit operating ambient temperature range is relatively narrow (19-109 ℉) and can not adjust the size of the cooling / heating capacity of the indoor temperature changes, the machine open between stops, the indoor temperature fluctuations, feels suddenly cold suddenly hot. | |||||||
Frequency Machine: the outdoor unit operating ambient temperature range is wide (-13-126 ℉) and can change depending on the temperature and adjust the size of the room cooling / heating capacity, the indoor temperature a smooth transition, the temperature fluctuation is small, automatic climate control, power consumption energy-saving effect is remarkable. |
Contact