EPS-ST-63100 | |||||||
MODEL | 6310-12 | 6310-24 | |||||
CH1 | CH2 | CH1 | CH2 | ||||
Output | DC Voltage | 12V | 13.5V | 24V | 25.2V | ||
Rated Current | 10A | 1A | 5A | 1A | |||
Current Range | 0~10A | 0-1A | 0~5A | 0-1A | |||
Charging Voltage | / | 13.5V | / | 27.6V | |||
Charge Current | / | 0~1A | / | 0~1A | |||
Rated Power | 120W | / | 120W | / | |||
Ripple & Noise Max(Note2) | 120mVp-p | 120mVp-p | 120mVp-p | 120mVp-p | |||
Voltage Adj. Range | ±10% | ±10% | ±10% | ±10% | |||
Voltage Tolerance(Note 3) | ±5% | ±5% | ±5% | ±5% | |||
Line Regulation(Note 4) | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |||
Load Regulation(Note 5) | ±2.0% | ±2.0% | ±2.0% | ±2.0% | |||
Setup/Rise Time | 500ms,50ms/220Vac (Full load) | ||||||
Hold up time(Typ.) | 50ms/220Vac (Full load) | ||||||
Input | Voltage Range | 100~240Vac | |||||
Frequency Range | 50/60Hz | ||||||
Efficiency(Typ.) | 82% | ||||||
Ac Current(Typ.) | 2.9A/220Vac | ||||||
Inrush Current(Typ.) | 40A | ||||||
Leakage Current(Typ.) | 3.5mA | ||||||
Protection | Over Load protection | 105%~150% | |||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over Voltage protection | 78%~90% | ||||||
Protection type: Hiccup mode,recovers automatically after fault condition is removed | |||||||
Over Shoot protection | Protection mode: the device up mode, after removing the abnormal conditions can be automatically restored | ||||||
Features | Features Introduction | Battery floating long-line, high charging efficiency, battery saturation can be up to 90% | |||||
Stoped to prevent overcharging, effectively extending the battery life | |||||||
Mains / battery automatic switchover time is very short, without staff on duty | |||||||
Can directly start the UPS batteries to meet emergency needs of users | |||||||
Environment | Working Temp | -10℃~60℃ | |||||
Working Humidity | 20~90%RH, non-condensing | ||||||
Storage Temp/Humidity | -20℃~75℃ 10~98%RH, non-condensing | ||||||
Temp. Coefficient | ±0.03%/℃(0~50℃) | ||||||
Vibration | 10Min/1 cycle, period for 60min,each along X,Y,Z axes | ||||||
Safety & EMC(Note 7) | Safety Standards(Note 6) | GB4943,EN60950 | |||||
Withstand Voltage | I/P-O/P: 2.5KVAC I/P-FG: 1.5KVAC O/P-SFG: 1.5KVAC | ||||||
Isolation Resistance | I/P-O/P I/P-FG O/P-FG: 100M Ohms/500VDC/25℃/70%RH | ||||||
EMI Conduction Radiation | Compliance to :EN55022, EN61000-3-2,3, FCC part15,GB9254 class B,GB17625.1 | ||||||
EMS Immunity | Compliance to :EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A | ||||||
Others | MBTF | ≥100000h. | |||||
Dimension/Packing | 159*98*42m(L*W*H) /0.4KG;50pcs/20Kg | ||||||
Note | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf &47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation measurement: from 0% to rated load of 100% 6.In accordance with the requirements of GB4943.1 power applies only to an altitude of 2000 meters in the following areas and non-tropical climate conditions for Safe use. 7.The power supply is considered part of the system components, to be with terminal equipment related to electromagnetic compatibility Relevant confirmation.. |