REVERSE CARNOT CYCLE THEORY
1. The refrigerant suddenly drops to -20*C after the pressure is released. When the ultra-low temperature liquid refrigerant enters the absorption evaporator, it encounters about 20*C air passing through the air heat transfer (temperature difference: 40'C), and the ultra-low temperature refrigerant absorbs After the heat to the air, the temperature rises to 20C;
2. The refrigerant with a temperature of 20C enters the high-temperature compressor and is heated and pressurized, and then becomes a high-temperature high-pressure 80C gas-state discharge compressor to enter the heat exchanger.
3. The temperature at 80C vaporized refrigerant transfers heat energy to the low-temperature cold water in the heat exchanger, so that it becomes about 60C. The domestic hot water is pumped into the insulated water tank for storage and use, and the high-temperature refrigerant is released after heat release. It becomes a high pressure liquid.
4. The high-pressure liquid refrigerant is throttled and depressurized by the expansion valve and then becomes a low-pressure liquid state, so that it enters the evaporator to absorb heat again;
5. According to the reverse Carnot cycle principle, the compressor is continuously and repeatedly cycled. The whole process is the process of heat transfer. As long as the compressor is operated with one degree of electricity, it can absorb from the air to the equivalent of 3 degrees to 6 degrees. The heat generated is transferred to the water, and the energy saving and safety effects are very obvious.
Introduction to compressor
American imported brand gulun scroll compressor, high energy efficiency is more than 12% higher than the general piston compressor, good reliability, liquid impact resistance, high tolerance of impurities, low noise, small vibration.
Sheet metal shell introduction
1.2-1.5 thick anticorrosive steel plate with strong ability of preventing salt alkali and acid is used. Outdoor protective coating is sprayed on the surface to make it beautiful and good-looking.
Fan introduction
Iron case iron wind blade waterproof copper wire motor, with quiet, stable air volume, less vibration, eliminate the plastic fan blade rupture, deformation risk.
Introduction to evaporator
Hydrophilic, corrugated aluminum Bernstein and internal screw copper tube heat exchanger. High heat transfer efficiency and durability. The hydrophilic property makes the condensed water on the heat exchanger drain away quickly.
Introduction to fluorine circuit and valve
Fluorine valve body adopts Japanese heron palace, Emerson throttle valve, accurate opening, little leakage, ultra-low failure rate! All fluorine welding joints are welded with 5% silver solder, good toughness, strong welding joints, no cracking.
Introduction to circuit breakers and relays:
All circuit breakers, relays are imported from Korea LS electrical appliances, good quality, long service life
Introduction of screws
All fasteners are made of 304 stainless steel screws, never rust, easy to maintain high grade and beautiful folding!
Introduction to chassis
Each product adopts channel steel Qi whole welding, surface spraying outdoor protective coating, solid and firm, durable.
Introduction to electronic control system
Independent development, production of electronic control system, complete functions, easy maintenance. With timing, backwater, electric heating, defrosting, with solar energy and other functions, no external control box
Condenser (shell and tube)
The shell and tube condenser has the advantages of small volume, full heat exchange of water and fluorine, high heat exchange efficiency and strong anti-ice heave ability
5P cycle machine works to connect the top water supply | |||||||||||
Neutral line | Water supply pump | Neutral line | Water supply valve | Neutral line | Return valve | Neutral line | Circulating pump | Low water level opening | High water level switch | ||
N | 13 | N | 12 | N | 11 | N | 15 | 4 | 3 | 2 | 1 |
1 Upper circulation tube | 2 Water tank probe | 3 Water tank copper rod | 4 Lower circulation tube |
5 Y filter | 6 Circulating pump | 7 Low water level | 8 High water level |
9 Return water solenoid valve | 10 Backwater probe | 11 Backwater copper rod | 12 Water supply solenoid valve |
13 Return pipe | 14 Cold water pipe | 15 Water supply pump | 16 Electronic pressure switch |
17 Check valve |
5P low temperature cycle unit floor heating connection | |||||||||||
Pipeline anti-cold heating wire | Circulating pump | Water supply pump | Neutral line | Water supply valve | Neutral line | Return valve | Neutral line | Low water level switch | High water level switch | ||
17 | 15 | 13 | N | 12 | N | 11 | N | 4 | 3 | 2 | 1 |
1 Reserve unit scale cleaning port | 2 Water tank probe | 3 Pressure relief valve ≤0.7MPa | 4 Reserve unit scale cleaning port |
5 Y filter | 6 Circulating water pump 6-8T/h head 25m | 7 20-30L expansion tank | 8 Circulating pump AC contactor |
9 Circulating water pump | 10 Trap | 11 Automatic exhaust valve grounding heater | 12 Water collector |
13 Auto exhaust valve | 14 thermostat | 15 Grounded heating pipe |
Unit Type | PAKA-130A | PAKA-180A | PAKA-330A | PAKA-650A | PAKA-750A | PAKA-1500A | |
Rated hot water(L/h) | 160L/h | 240L/h | 400L/h | 800L/h | 1000L/h | 2000L/h | |
Rated power (KW) | 1.7kW | 2.8kW | 4.5kW | 9kW | 11kW | 22kW | |
Rated current (A) | 9A | 14A | 8.5A | 17A | 20A | 40A | |
Maximum power (KW) | 2.25kW | 4.2kW | 6.3kW | 12kW | 16kW | 32kW | |
Maximum current (A) | 12A | 18A | 13A | 25A | 28A | 56A | |
Rated water temperature | 55℃ | 55℃ | 55℃ | 55℃ | 55℃ | 55℃ | |
Maximum water temperature | 65℃ | 55℃ | 55℃ | 65℃ | 65℃ | 60℃ | |
Power supply | 200V/50Hz | 220V/50Hz | 380V~3N/50Hz | 380V~3N/50Hz | 380V~3N/50Hz | 380V~3N/50Hz | |
Anti-shock level | Class I | Class I | Class I | Class I | Class I | Class I | |
Protection level | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | IPX4 | |
Exhaust side maximum working pressure | 2.8 MPa | 3.0 MPa | 3.0 MPa | 3.0 MPa | 3.0 MPa | 3.0 MPa | |
Exhaust side minimum working pressure | 0.05 MPa | 0.05 MPa | 0.05 MPa | 0.05 MPa | 0.05 MPa | 0.05 MPa | |
Host quality | 60Kg | 135Kg | 180Kg | 450Kg | 450Kg | 850Kg | |
Dimensions | Length | 500mm | 685mm | 850mm | 1210mm | 1210mm | 2160mm |
Width | 500mm | 670mm | 820mm | 900mm | 1080mm | 1210mm | |
Height | 650mm | 860mm | 1035mm | 1140mm | 2000mm | 2000mm | |
Host takeover size | DN20 | DN25 | DN25 | DN40 | DN40 | DN50 | |
External water pipe connection size | DN25 | DN32 | DN40 | DN50 | DN50 | DN50 | |
Unit rated circulating water (cubic) | 2.0-2.5 | 2.5-3.5 | 3.5-5 | 8-10 | 8-10 | 16-20 | |
Unit pump rated lift | 8 | 8 | 8 | 10 | 12 | 12 | |
Tap water pressure | ≤0.6 MPa | ≤0.6 MPa | ≤0.6 MPa | ≤0.6 MPa | ≤0.6 MPa | ≤0.6 MPa | |
Grounding requirements | ≤1 Ω | ≤1 Ω | ≤1 Ω | ≤10 Ω | ≤10 Ω | ≤10 Ω | |
Ambient temperature | 5-40℃ | 5-40℃ | 5-40℃ | 5-40℃ | 5-40℃ | 5-40℃ | |
Noise | ≤52dB(A) | 54dB(A) | 56dB(A) | 60dB(A) | 60dB(A) | 60dB(A) |
Widely used in: large, medium and small swimming pool constant temperature heating.