Representative Industry
Fan and Water pump, Stone Machinery, Extruder, Great Circle Machine, Fine Wire Drawing Machine, Air Compressor, Plastic Blow Molding Machine, Mining Winch, Belt Conveyor, Oil Pump, Ceramic Machine, as well as the application of open-loop vector control.
Product Overview
V5-H-GS series is a high-performance vector control inverter.
The product adopts the open-loop vector control technology with the current international advanced technology, which has the same excellent control performance with the international high-end inverter, At the same time, it is combined with the use characteristics of China, and it further strengthened the reliability and environmental adaptability of the product, as well as the customized and professional design. This greatly meet the needs of various transmission applications.
Control mode | open-loop vector control; |
Power range | 315kW~1200 kW |
Input voltage/ frequency | 3AC 380V~480V;50Hz/60Hz |
Output voltage | 3AC 0~rated input voltage |
Output frequency | 0.0~300.0Hz |
Digital input and output port | standard multi-function input port, expandable |
Analog input and output | input:AI1 0~20 MA, input impedance 500Ω,max input current 30MA;0~10V, input impedance 20kΩ,max input voltage 15V,resolution is 12 bits(0.025%)switch to choose 0~20 MA or 0~10V Analog input AI2 same as above explanation AI3 −10V~10,input impedance 20kΩ , max input voltage ±15V,resolution is 12bits(0.025%)output:AO1 0~20 MA, impedance with permissible output is 200~500Ω 0~10V,impedance with permissible output≥10kΩ,resolution is 10 bits(0.1%) short circuit protection,switch to choose 0~20 MA or 0~10V analog output AO2 same as above explanation |
Pulse input and output | pulse input:0.1Hz~50kHz;voltage range:24V±20% pulse output:0~50kHz;voltage range:24V±20% |
Communication protocol | dual 485 communication port supports Modbus protocol(RTU), standard operation panel meet remote control ,approximate 500 meter. |
External interface | DC24V power supply,max output current 100 MA |
Reactor | standard built-in input reactor, optional output reactor |
Installation | Vertical installation
|
IP | IP20 |
◪V5−H−4T□□□G−GS 3 Phase 400V Constant Torque/Heavy-duty Applications
Power(kW) | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | 800 | 900 | 1000 | 1250 | |
Motor(kW) | 315 | 355 | 400 | 450 | 500 | 560 | 630 | 710 | 800 | 900 | 1000 | 1250 | |
Output | Voltage(V) | 3 phase 0~rated input voltage | |||||||||||
Rated Current(A) | 600 | 650 | 690 | 775 | 860 | 950 | 1100 | 1300 | 1380 | 1550 | 1720 | 2200 | |
Overload capacity | 150% 1 min,180% 10 second, 200% 0.5 second,interval: 10 minutes (inverse time lag feature) | ||||||||||||
Input | Voltage/ frequency | 3 phase 380V~480V;50Hz/60Hz | |||||||||||
Allowable voltage range | 323V~528V;Voltage imbalance :≤3% ;allowable frequency fluctuation:±5% | ||||||||||||
Rated Current(A) | 552 | 624 | 670 | 755 | 840 | 920 | 1050 | 1248 | 1340 | 1510 | 1680 | 2100 | |
Braking unit | External braking unit needed | ||||||||||||
IP | IP54 | ||||||||||||
Cooling mode | Forced air cooling |
Note: V5−H−4T315G−GS and higher power grades are standard build-in input ;Optional output reactor
◪V5−H−6T□□□G−GS 3 Phase 690V Constant Torque/Heavy-duty Applications
Power(kW) | 400 | 450 | 500 | 560 | 630 | 710 | 800 | 900 | 1000 | 1250 | |
Motor(kW) | 400 | 450 | 500 | 560 | 630 | 710 | 800 | 900 | 1000 | 1250 | |
Output | Voltage(V) | 3 phase 0~Rated Voltage | |||||||||
Rated Current(A) | 435 | 490 | 545 | 600 | 680 | 770 | 860 | 980 | 1090 | 1540 | |
Overload capacity | 150% 1 min,180% 10 second, 200% 0.5 second,interval: 10 minutes (inverse time lag feature) | ||||||||||
Input | Voltage/ frequency | 3 phase 690V~790V;50Hz/60Hz | |||||||||
Allowable voltage range | 587V~793V;Voltage imbalance:≤3% ;allowable frequency fluctuation:±5% | ||||||||||
Rated Current(A) | 415 | 466 | 520 | 580 | 655 | 750 | 840 | 932 | 1040 | 1500 | |
Rated Current(A) | Built-in as optional | ||||||||||
IP | IP54 | ||||||||||
Cooling mode | Forced air cooling |
Note: V5−H−6T400G−GS and higher power grade is standard build-in input ; Optional output reactor
◪Product appearance, installation dimensions, approximate weight
V5−H−4T315G−GS and higher power grade , V5−H−6T400G−GS and higher power grade
Voltage(V) | Model No. | Appearance, Installation Dimensions(mm) | Weight(kg) | Note | ||
W | H | D | ||||
400V | V5−H−4T315G−GS | 800 | 2315 | 600 | 430 | |
V5−H−4T355G−GS | 440 | standalone | ||||
V5−H−4T400G−GS | 450 | standalone | ||||
V5−H−4T450G−GS | 1000 | 2352 | 600 | 480 | standalone | |
V5−H−4T500G−GS | 480 | standalone | ||||
V5−H−4T560G−GS | 500 | standalone | ||||
V5−H−4T630G−GS | 520 | standalone | ||||
V5−H−4T710G−GS | 1250 | 2352 | 600 | 650 | standalone | |
V5−H−4T800G−GS | 2000 | 2352 | 600 | 920 | parallel operation | |
V5−H−4T900G−GS | 980 | parallel operation | ||||
V5−H−4T1000G−GS | 1000 | parallel operation | ||||
V5−H−4T1250G−GS | 1060 | parallel operation |
◪Selected Accessories/Expansion Cards
Type | Name | Model | Function Explanation | Reference |
operation panel | Text Display | EX−MT01 | optional matching man-machine operation interface - text display | P2−** |
Touch Screen | EX−MT02 | Standard operating interface - touch screen | P2−** | |
expansion cards | Power monitor card | EX−PA01 | input power with three phase is out of phase/transient power loss monitoring | P2−** |
Phase-sequence detection card | EX−PA02 | Phase sequence detection of input power supply with three-phase | P2−** | |
Speed tracking card | EX−PA03 | speed tracking | P2−** | |
External power rectification card | EX−RF01 | control power supply is provided by the external power supply | P2−** | |
Programmable CAN bus extension card | EX−CA05 |
| P2−** | |
Profibus DP communication card | EX−CA06 |
| P2−** |
Cabinet-type inverters are generally more powerful, and many companies' high-power inverters use splicing to achieve breakthroughs in power. This results in a cabinet-type inverter. Separate inverter (or power unit) splicing, plus peripheral auxiliary, protection, and control circuits, so that it can be used in the hands of customers without the need for panel assembly. , Cabinet type inverter, simple and reasonable structure, has good rain-proof function, suitable for use in open-air conditions, fully meet the needs of industrial production.
Contact
Supplier